• IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency

IVPA 3500A 24V Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency

IVPA3524
Rated Output Power
3500VA
Rated Output Power
2800W
Nominal DC Input Voltage
24V
Efficiency
95% (Line Mode)
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
  • IVPA 3500A 24V  Intelligent Adjustment High Level Protection Home Use Inverter 95% Efficiency
SPECIFICATION
INTRODUCTION
This IVPA Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment.
Product Appearance


Bypass charging function
Optional electricity and battery priority
Battery self-defined
50/60Hz compatible
Intelligent and safety
IVPA Inverter SPECIFICATIONS
Line Model Specifications
Model IVPA3524 IVPA5048 IVPA7548 IVPA10048
Rated Output Power (A) 3500VA 5000VA 7500VA 10000VA
Rated Output Power (W) 2800W 4000W 6000W 8000W
Norminal DC Input Voltage 24V 48V 48V 48V
Input Voltage Waveform Sinusoidal (Utility or generator)
Terminal Connection L-N HOT1-HOT2
Nominal Input Voltage 120Vac 220Vac
Low Line Disconnect 90±3Vac(UPS) 80±3Vac (APL) 170±7Vac(UPS) 90±7Vac (APL)
Low Line Re-connect AC Input Range 95±3Vac(UPS) 85±3Vac (APL) 180±7Vac(UPS) 100±7Vac (APL)
High Line Disconnect 140±3Vac 280±7Vac
High Line Re-connect 135±3Vac 270±7Vac
Max AC Input Voltage 140Vms 280Vms
Nominal Input Frequency 50Hz/60Hz
Low Line Frequency Disconnect 40±1Hz
Low Line Frequency Re-connect 42±1Hz
High Line Frequency Disconnect 65±1Hz
High Line Frequency Re-connect 63±1Hz
Output Voltage Waveform Synchronize with input voltage
Over-Load Protection (SMPS load) Overcurrent protector Air switch protection Overcurrent protector Air switch protection
Output Short Circuit Protection Overcurrent protector Air switch protection Overcurrent protector Air switch protection
Efficiency (Line mode) 95%
Transfer Time (AC to DC) 15ms (typical value)
Transfer Time (DC to AC) 15ms (typical value)/30ms (special value)
Pass Through Without Battery No
Overcurrent Protector (grid) 50A 63A 63A 63A
Utility Charge Mode Specifications
Input Voltage Range 80-140Vac 90-280Vac
Nominal Output Voltage Depends on The Battery Types
Max Charge Current 40A 50A 60A 80A
Charge Current Regulation 0-40A 0-50A 0-60A 0-80A
Battery Initial Voltage Circuit Breaker
Charger Short Circuit 50A 63A 63A 63A
Breaker Size Dependent on Battery Type or Self-defined
Over Charge Protection YES
Solar Charging & Utility Charging (MPPT built-in controller is optional)
Max PV Open Circuit Voltage 145Vdc 196Vdc 195Vdc 195Vdc
PV Voltage Working Range 30~145Vdc 60~195Vdc 60~195Vdc 60~195Vdc
Max Input Power 2200W 6600W 6600W 6600W
Max Solar Charging Current 80A 120A 120A 120A
Max Charging Current (Utility+Solar) 120A 170A 180A 200A
Charging Algorithm
Charging Way Three Phases:
Boost CC (constant current level)   --  Boost CV (constant voltage level)   --   Float (constant pressure level)
Charging Stage Transition Definitions (1) Boost CC Stage: If A/C input is appliled, the charger will run at full current in CC mode until the charger reaches the boost voltage.
(2) Boost CV Stage: the charger will keep the boost voltage in Boost CV mode until the T1 timer has run out.
Then drop the voltage down to the float voltage, when the charging current is lower than 20% setting value.
(3) Float Stage: In float mode, the voltage will stay at the float voltage. If the A/C is reconnected or the battery voltage drops belows
24Vdc/48Vdc, the charger will reset the cycle above.
Battery Type Setting Battery Type Boost CC, CV Float
24/48 24/48
AGM 28.8/57.6 27.2/54.4
Flooded 29.2/58.4 27.6/55.2
Self Defined Adjustable, up tp 31.5/61.0
Inverter Mode Specifications
Model IVPA3525 IVPA5048 IVPA7548 IVPA10048
Output Voltage Waveform Pure Sine Wave
Nominal Output Voltage 110/120/127Vac±5% (L-N) 220/240Vac±5% (HOT1-HOT2)
Split-Phase Output Voltage / 110/120Vac±5% (HOT1-N or HOT2-N)
Nominal Output Frequency (Hz) 50±0.3Hz/60±0.3Hz (adjustable)
Output Voltage Regulation ±5% rms
Peak Efficiency 90%
Over-Load Protection (SMPS load) 5s @≥150% load; 10s @ 105%-150% load
Surge Rating 2 times rated overload power 5S
Capable of Starting Electric YES
Output Short Circuit Protection YES
Norminal DC Input Voltage 24V 48V
Min DC Starting Voltage 23V 46V
Battery Low Voltage Alarm 23Vdc@load<50%
22Vdc@load≥50%
46Vdc@load<50%; 44Vdc@load≥50%
Battery Low Voltage Re-connection 23.5Vdc@load<50%
23Vdc@load≥50%
47Vdc@load<50%; 46Vdc@load≥50%
DC Low Voltage Disconnection 21.5Vdc@load<50%
21Vdc@load≥50%
43Vdc@load<50%; 42Vdc@load≥50%
High DC Input Alarm & Fault 31.5Vdc±0.4V 63Vdc±0.4V
High DC Input Recovery 31Vdc±0.4V 62Vdc±0.4V
General Specifications
Operating Temperature 0 ℃ ~ 40 ℃
Storage Temperature -15 ℃ ~ 60 ℃
Net Weight (KG) 30.4 KG 30 KG 38.1 KG 55.9 KG
Gross Weight (KG) 33.5 KG 32.8KG 41.6 KG 67.2 KG
Product Dimension (mm) 440*391*195 mm 494*420*195 mm 580*420*195 mm
Package Dimension (mm) 552*408*290 mm 607*540*290 mm 690*480*335 mm